<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Flow Measurement &#8211; Fluscon</title>
	<atom:link href="https://fluscon.com/en/urun-kategori/measurement-instrumentation/flow-measurement/feed/" rel="self" type="application/rss+xml" />
	<link>https://fluscon.com</link>
	<description>Fluid Control Systems</description>
	<lastBuildDate>Sun, 04 Dec 2022 13:38:32 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.4</generator>

<image>
	<url>https://fluscon.com/wp-content/uploads/2022/07/cropped-qtq-95-32x32.png</url>
	<title>Flow Measurement &#8211; Fluscon</title>
	<link>https://fluscon.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Flow Switch</title>
		<link>https://fluscon.com/en/urunler/measurement-instrumentation/flow-measurement/flow-switch/</link>
		
		<dc:creator><![CDATA[Mehmet Akın]]></dc:creator>
		<pubDate>Sun, 06 Nov 2022 19:15:59 +0000</pubDate>
				<guid isPermaLink="false">http://fluscon.com/?post_type=product&#038;p=934</guid>

					<description><![CDATA[General Features Application Areas Liquids / Gases Measurement Methods Thermal Flow , Paddlewhell Connection Size DN15&#8230; DN600 Connection Norm Threaded / Flanged / Dip Type Measuring Range 0,15 &#8230; 8 m/s &#8212; 30 &#8230;300 cm /s Wet Parts AISI 304SS / ECTFE Connection Parts AISI 304SS / C-PVC Preservation/Housing Aluminum / Plastic Analog Output Signal 4&#8230;20 [&#8230;]]]></description>
										<content:encoded><![CDATA[<h4>General Features</h4>
<table width="386">
<tbody>
<tr>
<td width="159">Application Areas</td>
<td width="227">Liquids / Gases</td>
</tr>
<tr>
<td>Measurement Methods</td>
<td>Thermal Flow , Paddlewhell</td>
</tr>
<tr>
<td>Connection Size</td>
<td>DN15&#8230; DN600</td>
</tr>
<tr>
<td>Connection Norm</td>
<td>Threaded / Flanged / Dip Type</td>
</tr>
<tr>
<td>Measuring Range</td>
<td>0,15 &#8230; 8 m/s &#8212; 30 &#8230;300 cm /s</td>
</tr>
<tr>
<td>Wet Parts</td>
<td>AISI 304SS / ECTFE</td>
</tr>
<tr>
<td>Connection Parts</td>
<td>AISI 304SS / C-PVC</td>
</tr>
<tr>
<td>Preservation/Housing</td>
<td>Aluminum / Plastic</td>
</tr>
<tr>
<td>Analog Output Signal</td>
<td>4&#8230;20 mA</td>
</tr>
<tr>
<td>Digital Output Signal</td>
<td>SPST &#8211; SPDT &#8211; PNP -NO/NC Contact</td>
</tr>
<tr>
<td>Communication Protocol</td>
<td>Not Included</td>
</tr>
<tr>
<td>Supply Voltage</td>
<td>24 VDC / 230 VAC</td>
</tr>
<tr>
<td>Protection Class</td>
<td>IP65/IP67</td>
</tr>
<tr>
<td>Approval</td>
<td>Eex d IIC T4</td>
</tr>
<tr>
<td>Detection Range</td>
<td>0,15 m/s (Liquids) &#8212; 30 cm/s Gasses</td>
</tr>
<tr>
<td>Display Settings</td>
<td>Led On / Sequential Led</td>
</tr>
<tr>
<td>Display Paremeters</td>
<td>Instant Flow</td>
</tr>
<tr>
<td>Temperature</td>
<td>-20 &#8230; +80 °C ( Opt.150 °C )</td>
</tr>
<tr>
<td>Pressure</td>
<td>10 bar /  Opt.60 bar</td>
</tr>
<tr>
<td>Quality Certificate</td>
<td>IS09001 / CE</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Float Flowmeter / Rotameter</title>
		<link>https://fluscon.com/en/urunler/measurement-instrumentation/flow-measurement/float-flowmeter-rotameter/</link>
		
		<dc:creator><![CDATA[Mehmet Akın]]></dc:creator>
		<pubDate>Sun, 06 Nov 2022 19:09:34 +0000</pubDate>
				<guid isPermaLink="false">http://fluscon.com/?post_type=product&#038;p=931</guid>

					<description><![CDATA[General Features Application Areas Liquids / Oils / Gases Connection Size 1/4&#8243; &#8230; 4&#8243; Connection Norm Threaded, Flanged, Hygienic Clamp, PVC Bonding Measuring Range  10 cc/min &#8230; 400 Nm3/h Function Process Specific Solution Scale Solution According to Fluid Manual Control Available (With Control Valve) Measurement Method Variable Area Analog Output Signal 4&#8230;20 mA Digital Output [&#8230;]]]></description>
										<content:encoded><![CDATA[<h4>General Features</h4>
<table width="506">
<tbody>
<tr>
<td width="145">Application Areas</td>
<td width="361">Liquids / Oils / Gases</td>
</tr>
<tr>
<td>Connection Size</td>
<td>1/4&#8243; &#8230; 4&#8243;</td>
</tr>
<tr>
<td>Connection Norm</td>
<td>Threaded, Flanged, Hygienic Clamp, PVC Bonding</td>
</tr>
<tr>
<td>Measuring Range</td>
<td> 10 cc/min &#8230; 400 Nm3/h</td>
</tr>
<tr>
<td rowspan="2">Function</td>
<td>Process Specific Solution</td>
</tr>
<tr>
<td>Scale Solution According to Fluid</td>
</tr>
<tr>
<td>Manual Control</td>
<td>Available (With Control Valve)</td>
</tr>
<tr>
<td>Measurement Method</td>
<td>Variable Area</td>
</tr>
<tr>
<td>Analog Output Signal</td>
<td>4&#8230;20 mA</td>
</tr>
<tr>
<td>Digital Output Signal</td>
<td>SPST Contact</td>
</tr>
<tr>
<td>Measuring Tubes</td>
<td>Acrylic Plastic, Glass</td>
</tr>
<tr>
<td>Contact Voltage</td>
<td>24 VDC/230 VAC</td>
</tr>
<tr>
<td>Housing</td>
<td>Metal Enclosure ( Opt. )</td>
</tr>
<tr>
<td>Approval</td>
<td>Non-Explosive Sites</td>
</tr>
<tr>
<td>Sensitivity</td>
<td>% 2 Std. ( %1  Opt. )</td>
</tr>
<tr>
<td>Display Options</td>
<td>Black Scale ( Std. ) OpsRed Scale / Blue Scale</td>
</tr>
<tr>
<td>Temperature</td>
<td>-20 &#8230; +60 °C ( Opt.125 °C )</td>
</tr>
<tr>
<td>Pressure</td>
<td>Plastic Tube Max.10 bar , Glass Tube 6 bar / 16 bar (Opt.)</td>
</tr>
<tr>
<td>Quality Certificates</td>
<td>IS09001 / CE</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Metal Tube Flowmeter</title>
		<link>https://fluscon.com/en/urunler/measurement-instrumentation/flow-measurement/metal-tube-flowmeter/</link>
		
		<dc:creator><![CDATA[Mehmet Akın]]></dc:creator>
		<pubDate>Sun, 06 Nov 2022 19:07:32 +0000</pubDate>
				<guid isPermaLink="false">http://fluscon.com/?post_type=product&#038;p=927</guid>

					<description><![CDATA[General Features Application Areas Liquids / Oils /Gases Connection Size 1/4&#8243; &#8230; 4&#8243; Connection Norm Threaded, Flanged, Hygienic Clamp, PVC Bonding Measuring Range  0,03 Nm3/h &#8230; 5000 Nm3/h Function Process Specific Solution Scale Solution Depending on The Fuild Manual Control Available (With Control Valve) Measurement Method Variable Area Analog Output Signal 4&#8230;20 mA Digital Output [&#8230;]]]></description>
										<content:encoded><![CDATA[<h4>General Features</h4>
<table width="544">
<tbody>
<tr>
<td width="145">Application Areas</td>
<td width="399">Liquids / Oils /Gases</td>
</tr>
<tr>
<td>Connection Size</td>
<td>1/4&#8243; &#8230; 4&#8243;</td>
</tr>
<tr>
<td>Connection Norm</td>
<td>Threaded, Flanged, Hygienic Clamp, PVC Bonding</td>
</tr>
<tr>
<td>Measuring Range</td>
<td> 0,03 Nm3/h &#8230; 5000 Nm3/h</td>
</tr>
<tr>
<td rowspan="2">Function</td>
<td>Process Specific Solution</td>
</tr>
<tr>
<td>Scale Solution Depending on The Fuild</td>
</tr>
<tr>
<td>Manual Control</td>
<td>Available (With Control Valve)</td>
</tr>
<tr>
<td>Measurement Method</td>
<td>Variable Area</td>
</tr>
<tr>
<td>Analog Output Signal</td>
<td>4&#8230;20 mA</td>
</tr>
<tr>
<td>Digital Output Signal</td>
<td>SPST Contact</td>
</tr>
<tr>
<td>Measuring Tubes</td>
<td>Stainless or Plastic Tube</td>
</tr>
<tr>
<td>Contact Voltage</td>
<td>24 VDC/230 VAC</td>
</tr>
<tr>
<td>Housing</td>
<td>Aluminum / Metal Housing ( Opt. )</td>
</tr>
<tr>
<td>Approval</td>
<td>Non-Explosive Sites</td>
</tr>
<tr>
<td>Sensitivity</td>
<td>% 2 Std. ( %1  Opt.)</td>
</tr>
<tr>
<td>Display Settings</td>
<td>Black Scale ( Std. ) OpsRed Scale / Blue Scale</td>
</tr>
<tr>
<td>Temperature</td>
<td>-20 &#8230; 150°C ( Opt.300°C )</td>
</tr>
<tr>
<td>Pressure</td>
<td>Plastic Tube Max.10 bar , Metal Tube 40 bar (Opt.) 200 bar</td>
</tr>
<tr>
<td>Quality Certificates</td>
<td>IS09001 / CE</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Vortex Flowmeter</title>
		<link>https://fluscon.com/en/urunler/measurement-instrumentation/flow-measurement/vortex-flowmeter/</link>
		
		<dc:creator><![CDATA[Mehmet Akın]]></dc:creator>
		<pubDate>Sun, 06 Nov 2022 19:03:29 +0000</pubDate>
				<guid isPermaLink="false">http://fluscon.com/?post_type=product&#038;p=923</guid>

					<description><![CDATA[General Features Application Area  Liquids, Gases, Steam Measurement Parameters Instant and Total Flow Amount, Temperature and Pressure Measurement Temperature -50 &#8230; +150 °C / Opt. 350 °C Pressure Max. 40 Bar Connection Size DN25 &#8230; DN300 Connection Norm DIN,JIS,ANSI Measuring Range 0,5 &#8230; 12 m3/h / 508 &#8230; 12254 m3/h Wet Portions Stainless Steel Connection Portions Stainless Steel Preservation [&#8230;]]]></description>
										<content:encoded><![CDATA[<h4>General Features</h4>
<table width="628">
<tbody>
<tr>
<td width="167">Application Area</td>
<td width="461"> Liquids, Gases, Steam</td>
</tr>
<tr>
<td>Measurement Parameters</td>
<td>Instant and Total Flow Amount, Temperature and Pressure Measurement</td>
</tr>
<tr>
<td>Temperature</td>
<td>-50 &#8230; +150 °C / Opt. 350 °C</td>
</tr>
<tr>
<td>Pressure</td>
<td>Max. 40 Bar</td>
</tr>
<tr>
<td>Connection Size</td>
<td>DN25 &#8230; DN300</td>
</tr>
<tr>
<td>Connection Norm</td>
<td>DIN,JIS,ANSI</td>
</tr>
<tr>
<td>Measuring Range</td>
<td>0,5 &#8230; 12 m3/h / 508 &#8230; 12254 m3/h</td>
</tr>
<tr>
<td>Wet Portions</td>
<td>Stainless Steel</td>
</tr>
<tr>
<td>Connection Portions</td>
<td>Stainless Steel</td>
</tr>
<tr>
<td>Preservation</td>
<td>Epoxy Coated Aluminum</td>
</tr>
<tr>
<td>Analog Output Signal</td>
<td>4&#8230;20 mA</td>
</tr>
<tr>
<td>Digital Output Signal</td>
<td>Puls/Frequency</td>
</tr>
<tr>
<td>Communication Protocol</td>
<td>HART,RS-485 Modbus, Profibus Pa ,Foundation Fieldbus</td>
</tr>
<tr>
<td>Supply Voltage</td>
<td>24 VDC , 230 VAC</td>
</tr>
<tr>
<td>Protection Class</td>
<td>IP67/IP68</td>
</tr>
<tr>
<td>Approval</td>
<td>Ex d , Exia</td>
</tr>
<tr>
<td>Sensitivity</td>
<td>% 0,5 Std. ( %0,1 .. %0,2 Opt.)</td>
</tr>
<tr>
<td>Display Options</td>
<td>Compact , Remote</td>
</tr>
<tr>
<td>Display Paremeters</td>
<td>Instant and Total Flow Amount</td>
</tr>
<tr>
<td>Quality Certificates</td>
<td>IS09001 / CE</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Coriolis Mass Flowmeter</title>
		<link>https://fluscon.com/en/urunler/measurement-instrumentation/flow-measurement/coriolis-mass-flowmeter/</link>
		
		<dc:creator><![CDATA[Mehmet Akın]]></dc:creator>
		<pubDate>Sun, 06 Nov 2022 19:00:33 +0000</pubDate>
				<guid isPermaLink="false">http://fluscon.com/?post_type=product&#038;p=920</guid>

					<description><![CDATA[General Features Application Area  Liquids , Gases Measurement Parameters Instant and total flow, Temperature and Density Measurement Temperature -50 &#8230; +150 °C / Opt. 350 °C Pressure Max. 250 Bar Connection Size DN10 &#8230; DN300 Connection Norm DIN,JIS,ANSI Measuring Range 0,12 &#8230; 18 kg/h / 30 &#8230; 1500 t/h Wet Portions Stainless Steel Connection Portions Stainless Steel [&#8230;]]]></description>
										<content:encoded><![CDATA[<h4>General Features</h4>
<table width="562">
<tbody>
<tr>
<td width="167">Application Area</td>
<td width="395"> Liquids , Gases</td>
</tr>
<tr>
<td>Measurement Parameters</td>
<td>Instant and total flow, Temperature and Density Measurement</td>
</tr>
<tr>
<td>Temperature</td>
<td>-50 &#8230; +150 °C / Opt. 350 °C</td>
</tr>
<tr>
<td>Pressure</td>
<td>Max. 250 Bar</td>
</tr>
<tr>
<td>Connection Size</td>
<td>DN10 &#8230; DN300</td>
</tr>
<tr>
<td>Connection Norm</td>
<td>DIN,JIS,ANSI</td>
</tr>
<tr>
<td>Measuring Range</td>
<td>0,12 &#8230; 18 kg/h / 30 &#8230; 1500 t/h</td>
</tr>
<tr>
<td>Wet Portions</td>
<td>Stainless Steel</td>
</tr>
<tr>
<td>Connection Portions</td>
<td>Stainless Steel</td>
</tr>
<tr>
<td>Precision/Housing</td>
<td>Epoxy covered Aliminium</td>
</tr>
<tr>
<td>Analog Output Signal</td>
<td>4&#8230;20 mA</td>
</tr>
<tr>
<td>Digital Output Signal</td>
<td>Puls/Frequens</td>
</tr>
<tr>
<td>Communication Protocol</td>
<td>HART,RS-485 Modbus, Profibus Pa ,Foundation Fieldbus</td>
</tr>
<tr>
<td>Supply Voltage</td>
<td>24 VDC , 230 VAC</td>
</tr>
<tr>
<td>Preservation Class</td>
<td>IP67/IP68</td>
</tr>
<tr>
<td>Approval</td>
<td>Ex d , Exia</td>
</tr>
<tr>
<td>Precision</td>
<td>% 0,5 Std. ( %0,1 .. %0,2 Opt.)</td>
</tr>
<tr>
<td>Indicator Options</td>
<td>Compact , Remote ( Seperate )</td>
</tr>
<tr>
<td>Indicator Paremeters</td>
<td>Instant and total flow</td>
</tr>
<tr>
<td>Quality Certifaces</td>
<td>IS09001 / CE</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Orifice Plate Flowmeter</title>
		<link>https://fluscon.com/en/urunler/measurement-instrumentation/flow-measurement/orifice-plate-flowmeter/</link>
		
		<dc:creator><![CDATA[Mehmet Akın]]></dc:creator>
		<pubDate>Sun, 06 Nov 2022 18:58:34 +0000</pubDate>
				<guid isPermaLink="false">http://fluscon.com/?post_type=product&#038;p=917</guid>

					<description><![CDATA[General Features Application Area Liquids, Gases, Steam Temperature  Max. 450 °C Pressure Max. 137 bar Connection Size DN10 &#8230; DN 600 Connection Norm DIN,JIS,ANSI Flange , Sandwich ( Wafer ) or Geared Connection Measuring Range 150 m/s ( Production possibility specific to your process ) Wet Portions Stainless Steel Connection Portions Stainless Steel Preservation/Housing Epoxy Coated Aluminum Analog [&#8230;]]]></description>
										<content:encoded><![CDATA[<h4>General Features</h4>
<table width="550">
<tbody>
<tr>
<td width="159">Application Area</td>
<td width="391">Liquids, Gases, Steam</td>
</tr>
<tr>
<td>Temperature</td>
<td> Max. 450 °C</td>
</tr>
<tr>
<td>Pressure</td>
<td>Max. 137 bar</td>
</tr>
<tr>
<td>Connection Size</td>
<td>DN10 &#8230; DN 600</td>
</tr>
<tr>
<td>Connection Norm</td>
<td>DIN,JIS,ANSI Flange , Sandwich ( Wafer ) or Geared Connection</td>
</tr>
<tr>
<td>Measuring Range</td>
<td>150 m/s ( Production possibility specific to your process )</td>
</tr>
<tr>
<td>Wet Portions</td>
<td>Stainless Steel</td>
</tr>
<tr>
<td>Connection Portions</td>
<td>Stainless Steel</td>
</tr>
<tr>
<td>Preservation/Housing</td>
<td>Epoxy Coated Aluminum</td>
</tr>
<tr>
<td>Analog Output Signal</td>
<td>4&#8230;20 mA</td>
</tr>
<tr>
<td>Digital Output Signal</td>
<td>Puls/Frequence</td>
</tr>
<tr>
<td>Communication Protocol</td>
<td>HART,RS-485 Modbus, Profibus Pa ,Foundation Fieldbus</td>
</tr>
<tr>
<td>Supply Voltage</td>
<td>24 VDC</td>
</tr>
<tr>
<td>Protection Class</td>
<td>IP67/IP68</td>
</tr>
<tr>
<td>Approval</td>
<td>Ex d , Exia</td>
</tr>
<tr>
<td>Precision</td>
<td>% 1 Std. ( %0,5 .. %0,2 Opt.)</td>
</tr>
<tr>
<td>Indicator Options</td>
<td>Compact , Remote</td>
</tr>
<tr>
<td>Indicator Parameters</td>
<td>Instant and Total Flow Amount</td>
</tr>
<tr>
<td>Quality Certificates</td>
<td>IS09001 / CE</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Pitot Tube Flowmetter</title>
		<link>https://fluscon.com/en/urunler/measurement-instrumentation/flow-measurement/pitot-tube-flowmetter/</link>
		
		<dc:creator><![CDATA[Mehmet Akın]]></dc:creator>
		<pubDate>Sun, 06 Nov 2022 18:53:28 +0000</pubDate>
				<guid isPermaLink="false">http://fluscon.com/?post_type=product&#038;p=911</guid>

					<description><![CDATA[General Features Application Area  Liquids , Gases , Steam Temperature  Max 1000 °C Pressure Max. 200 bar Connection Size DN50 &#8230; DN 1200 Connection Norm DIN,JIS,ANSI Flange or Plunge Type Measuring Range 150 m/s ( Production possibility depending on your process ) Wet Portions Stainless Steel Connection Portions Stainless Steel Preservation/Housing Epoxy Coated Aluminum Analog Output Signal [&#8230;]]]></description>
										<content:encoded><![CDATA[<h4>General Features</h4>
<table width="540">
<tbody>
<tr>
<td width="159">Application Area</td>
<td width="381"> Liquids , Gases , Steam</td>
</tr>
<tr>
<td>Temperature</td>
<td> Max 1000 °C</td>
</tr>
<tr>
<td>Pressure</td>
<td>Max. 200 bar</td>
</tr>
<tr>
<td>Connection Size</td>
<td>DN50 &#8230; DN 1200</td>
</tr>
<tr>
<td>Connection Norm</td>
<td>DIN,JIS,ANSI Flange or Plunge Type</td>
</tr>
<tr>
<td>Measuring Range</td>
<td>150 m/s ( Production possibility depending on your process )</td>
</tr>
<tr>
<td>Wet Portions</td>
<td>Stainless Steel</td>
</tr>
<tr>
<td>Connection Portions</td>
<td>Stainless Steel</td>
</tr>
<tr>
<td>Preservation/Housing</td>
<td>Epoxy Coated Aluminum</td>
</tr>
<tr>
<td>Analog Output Signal</td>
<td>4&#8230;20 mA</td>
</tr>
<tr>
<td>Digital Output Signal</td>
<td>Puls/Frequency</td>
</tr>
<tr>
<td>Communication Protocol</td>
<td>HART,RS-485 Modbus, Profibus Pa ,Foundation Fieldbus</td>
</tr>
<tr>
<td>Supply Voltage</td>
<td>24 VDC</td>
</tr>
<tr>
<td>Protection Class</td>
<td>IP67/IP68</td>
</tr>
<tr>
<td>Approval</td>
<td>Ex d , Exia</td>
</tr>
<tr>
<td>Precision</td>
<td>% 1 Std. ( %0,5 .. %0,2 Opt.)</td>
</tr>
<tr>
<td>Indicator Options</td>
<td>Compact , Remote</td>
</tr>
<tr>
<td>Indicator Parameters</td>
<td>Instant and Total Flow Amount</td>
</tr>
<tr>
<td>Quality Certificates</td>
<td>
<h4>IS09001 / CE</h4>
</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Ultrasonic Flowmeter</title>
		<link>https://fluscon.com/en/urunler/measurement-instrumentation/flow-measurement/ultrasonic-flowmeter/</link>
		
		<dc:creator><![CDATA[Mehmet Akın]]></dc:creator>
		<pubDate>Sun, 06 Nov 2022 18:47:04 +0000</pubDate>
				<guid isPermaLink="false">http://fluscon.com/?post_type=product&#038;p=908</guid>

					<description><![CDATA[General Features Application Area  Liquids, Gases Function Stationary and Portable (Portable) Application Area Penstock Pipes, All Metal and Plastic Pipes Temperature -20 &#8230; +90 °C Std.  / Opt.160 °C Building Clamp On ( 2 / 4 / 8 Transducer ) Connection Size DN15 &#8230; DN7000 Connection Norm Clamp Mounting Measuring Range 0,3 &#8230; 20 m/sn Connection Portions [&#8230;]]]></description>
										<content:encoded><![CDATA[<h4>General Features</h4>
<table width="560">
<tbody>
<tr>
<td width="159">Application Area</td>
<td width="401"> Liquids, Gases</td>
</tr>
<tr>
<td>Function</td>
<td>Stationary and Portable (Portable)</td>
</tr>
<tr>
<td>Application Area</td>
<td>Penstock Pipes, All Metal and Plastic Pipes</td>
</tr>
<tr>
<td>Temperature</td>
<td>-20 &#8230; +90 °C Std.  / Opt.160 °C</td>
</tr>
<tr>
<td>Building</td>
<td>Clamp On ( 2 / 4 / 8 Transducer )</td>
</tr>
<tr>
<td>Connection Size</td>
<td>DN15 &#8230; DN7000</td>
</tr>
<tr>
<td>Connection Norm</td>
<td>Clamp Mounting</td>
</tr>
<tr>
<td>Measuring Range</td>
<td>0,3 &#8230; 20 m/sn</td>
</tr>
<tr>
<td>Connection Portions</td>
<td>Stainless steel, Carbon Steel</td>
</tr>
<tr>
<td rowspan="2">Accessory</td>
<td>Clamp, Tape Measure, Liquid Gel, Carry Case</td>
</tr>
<tr>
<td>Ops. Pipe Thickness Gauge</td>
</tr>
<tr>
<td>Analog Output Signal</td>
<td>4&#8230;20 mA</td>
</tr>
<tr>
<td>Dijital Output Signal</td>
<td>Puls/Frequency</td>
</tr>
<tr>
<td>Communication Protocol</td>
<td>HART,RS232, RS-485 , Modbus, Profibus Pa ,Foundation Fieldbus</td>
</tr>
<tr>
<td>Supply Voltage</td>
<td>24 VDC , 230 VAC , With Battery</td>
</tr>
<tr>
<td>Protection Class</td>
<td>IP65/IP68</td>
</tr>
<tr>
<td>Approval</td>
<td>Non-Explosive Fields</td>
</tr>
<tr>
<td>Precision</td>
<td>% 1 Std. ( %0,5 )</td>
</tr>
<tr>
<td>Display Options</td>
<td>Handheld, Remote</td>
</tr>
<tr>
<td>Display Parameters</td>
<td>Instant and Total Flow Amount, Speed, Signal Quality</td>
</tr>
<tr>
<td>Alarm Parameters</td>
<td>Low / High Flow Rate, Empty Pipe Alarm</td>
</tr>
<tr>
<td>Quality Certificates</td>
<td>IS09001 / CE</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Thermal Mass Flowmeter</title>
		<link>https://fluscon.com/en/urunler/measurement-instrumentation/flow-measurement/thermal-mass-flowmeter/</link>
		
		<dc:creator><![CDATA[Mehmet Akın]]></dc:creator>
		<pubDate>Sun, 06 Nov 2022 18:32:48 +0000</pubDate>
				<guid isPermaLink="false">http://fluscon.com/?post_type=product&#038;p=904</guid>

					<description><![CDATA[General Features Application Area  Gas ( Dry non-humid gases ) Temperature  -40 &#8230; +230 °C Pressure Max. 40 bar Connection Size DN25 &#8230; DN 600 Connection Range Threaded Connection Measuring Range 0&#8230;150 m/s Wet Portions Stainless Steel Connection Portions Stainless Steel Analog Output Signal 4&#8230;20 mA / 0&#8230;10 VDC / 0&#8230;5 VDC Communication Protocol RS485 Modbus, [&#8230;]]]></description>
										<content:encoded><![CDATA[<h4>General Features</h4>
<table width="382">
<tbody>
<tr>
<td width="191">Application Area</td>
<td width="191"> Gas ( Dry non-humid gases )</td>
</tr>
<tr>
<td>Temperature</td>
<td> -40 &#8230; +230 °C</td>
</tr>
<tr>
<td>Pressure</td>
<td>Max. 40 bar</td>
</tr>
<tr>
<td>Connection Size</td>
<td>DN25 &#8230; DN 600</td>
</tr>
<tr>
<td>Connection Range</td>
<td>Threaded Connection</td>
</tr>
<tr>
<td>Measuring Range</td>
<td>0&#8230;150 m/s</td>
</tr>
<tr>
<td>Wet Portions</td>
<td>Stainless Steel</td>
</tr>
<tr>
<td>Connection Portions</td>
<td>Stainless Steel</td>
</tr>
<tr>
<td>Analog Output Signal</td>
<td>4&#8230;20 mA / 0&#8230;10 VDC / 0&#8230;5 VDC</td>
</tr>
<tr>
<td rowspan="2">Communication Protocol</td>
<td>RS485 Modbus, HART , Profibus PA</td>
</tr>
<tr>
<td>Foundation Fieldbus</td>
</tr>
<tr>
<td>Supply Voltage</td>
<td>24 VDC</td>
</tr>
<tr>
<td>Protection Class</td>
<td>IP65 / IP67</td>
</tr>
<tr>
<td>Approval</td>
<td>Ex d , Ex ia</td>
</tr>
<tr>
<td>Precision</td>
<td>% 1 Std. ( %0,5 .. %0,2 Opt.)</td>
</tr>
<tr>
<td>Indicator Options</td>
<td>Compact , Remote</td>
</tr>
<tr>
<td>Indicator Paremeters</td>
<td>Instant and Total Flow</td>
</tr>
<tr>
<td>Quality Certifaces</td>
<td>IS09001 / CE</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Oval Gear Flowmeter</title>
		<link>https://fluscon.com/en/urunler/measurement-instrumentation/flow-measurement/oval-gear-flowmeter/</link>
		
		<dc:creator><![CDATA[Mehmet Akın]]></dc:creator>
		<pubDate>Sun, 06 Nov 2022 17:35:39 +0000</pubDate>
				<guid isPermaLink="false">http://fluscon.com/?post_type=product&#038;p=884</guid>

					<description><![CDATA[General Features Application Areas Viscous Liquids Connection Size M5 &#8230; DN100 Connection Norm Threaded, Flanged, Hygienic Clamp Measuring Range 10 cc/min  &#8230; 20 m3/hour Wet Portions G015 &#8230; G045  AISI316 VZS                  Aluminum , Pom F380                Polypropylene, ECTFE Connection Portions Stainless Steel, [&#8230;]]]></description>
										<content:encoded><![CDATA[<h4>General Features</h4>
<table width="588">
<tbody>
<tr>
<td width="163">Application Areas</td>
<td width="425">Viscous Liquids</td>
</tr>
<tr>
<td>Connection Size</td>
<td>M5 &#8230; DN100</td>
</tr>
<tr>
<td>Connection Norm</td>
<td>Threaded, Flanged, Hygienic Clamp</td>
</tr>
<tr>
<td>Measuring Range</td>
<td>10 cc/min  &#8230; 20 m3/hour</td>
</tr>
<tr>
<td rowspan="3">Wet Portions</td>
<td>G015 &#8230; G045  AISI316</td>
</tr>
<tr>
<td>VZS                  Aluminum , Pom</td>
</tr>
<tr>
<td>F380                Polypropylene, ECTFE</td>
</tr>
<tr>
<td>Connection Portions</td>
<td>Stainless Steel, Polymer Groups</td>
</tr>
<tr>
<td>Housing</td>
<td>Stainless Steel / Plastic</td>
</tr>
<tr>
<td>Analog Output Signal</td>
<td>4&#8230;20 mA</td>
</tr>
<tr>
<td>Digital Output Signal</td>
<td>Puls</td>
</tr>
<tr>
<td>Communication Protocol</td>
<td>Not Included</td>
</tr>
<tr>
<td>Supply Voltage</td>
<td>24 VDC</td>
</tr>
<tr>
<td>Protection Class</td>
<td>IP65/IP67</td>
</tr>
<tr>
<td>Approval</td>
<td>Ex d II C T6</td>
</tr>
<tr>
<td>Sensitivity</td>
<td>% 0,5 Std. ( %0,1 .. %0,1 Opt.)</td>
</tr>
<tr>
<td>Display Options</td>
<td>Compact , Remote</td>
</tr>
<tr>
<td>Display Paremeters</td>
<td>Instant and Total Flow Amount</td>
</tr>
<tr>
<td>Temperature</td>
<td>-40 &#8230; +60 °C ( Opt.225 °C )</td>
</tr>
<tr>
<td>Pressure</td>
<td>6 bar / 10 bar /  Opt.400 bar</td>
</tr>
<tr>
<td>Quality Certificates</td>
<td>IS09001 / CE</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
