<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Pressure Measurement &#8211; Fluscon</title>
	<atom:link href="https://fluscon.com/en/urun-kategori/measurement-instrumentation/pressure-measurement/feed/" rel="self" type="application/rss+xml" />
	<link>https://fluscon.com</link>
	<description>Fluid Control Systems</description>
	<lastBuildDate>Tue, 06 Dec 2022 10:24:11 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.4</generator>

<image>
	<url>https://fluscon.com/wp-content/uploads/2022/07/cropped-qtq-95-32x32.png</url>
	<title>Pressure Measurement &#8211; Fluscon</title>
	<link>https://fluscon.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Manometer</title>
		<link>https://fluscon.com/en/urunler/measurement-instrumentation/pressure-measurement/manometer/</link>
		
		<dc:creator><![CDATA[Mehmet Akın]]></dc:creator>
		<pubDate>Sat, 27 Aug 2022 15:03:26 +0000</pubDate>
				<guid isPermaLink="false">http://fluscon.com/?post_type=product&#038;p=613</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Digital Pressure Gauge</title>
		<link>https://fluscon.com/en/urunler/measurement-instrumentation/pressure-measurement/digital-pressure-gauge/</link>
		
		<dc:creator><![CDATA[Mehmet Akın]]></dc:creator>
		<pubDate>Sat, 27 Aug 2022 15:00:18 +0000</pubDate>
				<guid isPermaLink="false">http://fluscon.com/?post_type=product&#038;p=611</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Differential Pressure Switch</title>
		<link>https://fluscon.com/en/urunler/measurement-instrumentation/pressure-measurement/differential-pressure-switch/</link>
		
		<dc:creator><![CDATA[Mehmet Akın]]></dc:creator>
		<pubDate>Sat, 27 Aug 2022 14:54:03 +0000</pubDate>
				<guid isPermaLink="false">http://fluscon.com/?post_type=product&#038;p=606</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Pressure Switch</title>
		<link>https://fluscon.com/en/urunler/measurement-instrumentation/pressure-measurement/pressure-switch/</link>
		
		<dc:creator><![CDATA[Mehmet Akın]]></dc:creator>
		<pubDate>Sat, 27 Aug 2022 14:42:13 +0000</pubDate>
				<guid isPermaLink="false">http://fluscon.com/?post_type=product&#038;p=604</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Smart Differential Pressure Transmitter</title>
		<link>https://fluscon.com/en/urunler/measurement-instrumentation/pressure-measurement/smart-differential-pressure-transmitter/</link>
		
		<dc:creator><![CDATA[Mehmet Akın]]></dc:creator>
		<pubDate>Sat, 27 Aug 2022 14:29:15 +0000</pubDate>
				<guid isPermaLink="false">http://fluscon.com/?post_type=product&#038;p=600</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Diaphragm Smart Differential Pressure Transmitter</title>
		<link>https://fluscon.com/en/urunler/measurement-instrumentation/pressure-measurement/diyaframli-smart-fark-basinc-transmitter/</link>
		
		<dc:creator><![CDATA[Mehmet Akın]]></dc:creator>
		<pubDate>Sat, 27 Aug 2022 13:57:53 +0000</pubDate>
				<guid isPermaLink="false">http://fluscon.com/?post_type=product&#038;p=593</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Diaphragm Smart Pressure Transmitter</title>
		<link>https://fluscon.com/en/urunler/measurement-instrumentation/pressure-measurement/diaphragm-smart-pressure-transmitter/</link>
		
		<dc:creator><![CDATA[Mehmet Akın]]></dc:creator>
		<pubDate>Sat, 27 Aug 2022 13:50:26 +0000</pubDate>
				<guid isPermaLink="false">http://fluscon.com/?post_type=product&#038;p=515</guid>

					<description><![CDATA[<p><br data-mce-bogus="1"></p>]]></description>
										<content:encoded><![CDATA[<p><br data-mce-bogus="1"></p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Smart Pressure Transmitter</title>
		<link>https://fluscon.com/en/urunler/measurement-instrumentation/pressure-measurement/smart-pressure-transmitter/</link>
		
		<dc:creator><![CDATA[Mehmet Akın]]></dc:creator>
		<pubDate>Sat, 13 Aug 2022 16:46:23 +0000</pubDate>
				<guid isPermaLink="false">http://fluscon.com/?post_type=product&#038;p=512</guid>

					<description><![CDATA[General Specifications Application Area Wide Usage Area Measurement Range Full Durability against hard process conditins High Precision Intended for pressure and level applcations through the smart electronic Ability to model the Analog output Data Tracking of Volume and Mass at Level applications APT3200G3      -1 &#8230; +1,5  bar APT3200G4      -1 &#8230; +15   bar [&#8230;]]]></description>
										<content:encoded><![CDATA[<h4>General Specifications</h4>
<table width="887">
<tbody>
<tr>
<td width="171"><strong>Application Area</strong></td>
<td width="716">Wide Usage Area</td>
</tr>
<tr>
<td rowspan="10"><strong>Measurement Range</strong></td>
<td>Full Durability against hard process conditins</td>
</tr>
<tr>
<td>High Precision</td>
</tr>
<tr>
<td>Intended for pressure and level applcations through the smart electronic</td>
</tr>
<tr>
<td>Ability to model the Analog output</td>
</tr>
<tr>
<td>Data Tracking of Volume and Mass at Level applications</td>
</tr>
<tr>
<td>APT3200G3      -1 &#8230; +1,5  bar</td>
</tr>
<tr>
<td>APT3200G4      -1 &#8230; +15   bar</td>
</tr>
<tr>
<td>APT3200G5      0 &#8230; 50   bar</td>
</tr>
<tr>
<td>APT3200G6      0 &#8230; 250 bar</td>
</tr>
<tr>
<td>APT3200G7      0 &#8230; 600 bar</td>
</tr>
<tr>
<td><strong>Temperature</strong></td>
<td>-40 &#8230; +125 °C ( Opt.400°C)</td>
</tr>
<tr>
<td><strong>Connection Measurement</strong></td>
<td>1/4 &#8221; &#8230; 3 &#8220;</td>
</tr>
<tr>
<td><strong>Connection Norm</strong></td>
<td>G or NPT Norm Gear  / Flange ( ANSI,JIS ASME ) and Hygenic Clamp Connecion Norms</td>
</tr>
<tr>
<td><strong>Cable Union</strong></td>
<td>1/2&#8243; NPT , M20x1,5 , Ex Gland</td>
</tr>
<tr>
<td rowspan="2"><strong>Wet Parts</strong></td>
<td>Diaphragm AISI316 L, Hastelloy C ,Tantalum</td>
</tr>
<tr>
<td>Trunk      AISI316SS</td>
</tr>
<tr>
<td><strong>Connection Parts</strong></td>
<td>AISI316 L, Hastelloy C , Tantalum</td>
</tr>
<tr>
<td><strong>Preservation/Housing</strong></td>
<td>Epoxy Coated Aluminium / Stainess Steel</td>
</tr>
<tr>
<td><strong>Analog Output Signal</strong></td>
<td>4&#8230;20 mA</td>
</tr>
<tr>
<td><strong>Digital Communication</strong></td>
<td>HART</td>
</tr>
<tr>
<td><strong>Communication Protocol</strong></td>
<td>Opt.Modbus,Profibus PA , Foundation Fieldbus</td>
</tr>
<tr>
<td><strong>Supply Voltage</strong></td>
<td>10 &#8230; 45 VDC</td>
</tr>
<tr>
<td><strong>Protection Class</strong></td>
<td>IP67</td>
</tr>
<tr>
<td><strong>Approval</strong></td>
<td>Ex d II C T6 , Ex ia II C T6</td>
</tr>
<tr>
<td><strong>Precision</strong></td>
<td>% 0,075 Std. (Opt. %0,05 )</td>
</tr>
<tr>
<td><strong>Stability</strong></td>
<td> 0.125% URL/3 Years</td>
</tr>
<tr>
<td><strong>Indicator Options</strong></td>
<td>Compact , Remote ( Seperate )</td>
</tr>
<tr>
<td><strong>Indicator Parameters</strong></td>
<td>All Engineering Units , Percentage Value , Current Value ( Only one or all of them with rotating can be watched )</td>
</tr>
<tr>
<td><strong>Quality Certificates</strong></td>
<td>IS09001 / CE</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HVAC Differential Pressure Transmitter</title>
		<link>https://fluscon.com/en/urunler/measurement-instrumentation/pressure-measurement/hvac-differential-pressure-transmitter/</link>
		
		<dc:creator><![CDATA[Mehmet Akın]]></dc:creator>
		<pubDate>Sat, 13 Aug 2022 14:42:53 +0000</pubDate>
				<guid isPermaLink="false">http://fluscon.com/?post_type=product&#038;p=505</guid>

					<description><![CDATA[General Features &#160; Application Areas Low Cost HVAC -Suitable for building automation Air Differential Pressure Sensors Air Differential Pressure Keys Filtration Applications Non-caustic gasses Measurment Range &#8211; 25 Pascal &#8230; + 25 Pascal / 0 &#8230; 7000 Pascal Temperature -0 &#8230; +50 °C ( Opt.400°C) Connection Measurement 5 mm or 6,3 mm With Hose Inlet [&#8230;]]]></description>
										<content:encoded><![CDATA[<h3><strong>General Features<br />
</strong></h3>
<p>&nbsp;</p>
<table style="height: 423px;" width="699">
<tbody>
<tr>
<td rowspan="6" width="260"><strong>Application Areas</strong></td>
<td width="260">Low Cost</td>
</tr>
<tr>
<td>HVAC -Suitable for building automation</td>
</tr>
<tr>
<td>Air Differential Pressure Sensors</td>
</tr>
<tr>
<td>Air Differential Pressure Keys</td>
</tr>
<tr>
<td>Filtration Applications</td>
</tr>
<tr>
<td>Non-caustic gasses</td>
</tr>
<tr>
<td><strong>Measurment Range</strong></td>
<td>&#8211; 25 Pascal &#8230; + 25 Pascal / 0 &#8230; 7000 Pascal</td>
</tr>
<tr>
<td><strong>Temperature</strong></td>
<td>-0 &#8230; +50 °C ( Opt.400°C)</td>
</tr>
<tr>
<td><strong>Connection Measurement</strong></td>
<td>5 mm or 6,3 mm With Hose Inlet</td>
</tr>
<tr>
<td><strong>Cable Union</strong></td>
<td>M16</td>
</tr>
<tr>
<td><strong>Wet Parts</strong></td>
<td>PC</td>
</tr>
<tr>
<td><strong>Connection Parts</strong></td>
<td>PVC</td>
</tr>
<tr>
<td><strong>Preservation/Housing</strong></td>
<td>ABC</td>
</tr>
<tr>
<td><strong>Analog Output Signal</strong></td>
<td>4&#8230;20 mA / 0&#8230; 10 VDC</td>
</tr>
<tr>
<td><strong>Digital Output Signal</strong></td>
<td>NO/NC Contact</td>
</tr>
<tr>
<td><strong>Supply Voltage</strong></td>
<td>10 &#8230; 45 VDC</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>OEM Differential Pressure Transmitter</title>
		<link>https://fluscon.com/en/urunler/measurement-instrumentation/pressure-measurement/oem-differential-pressure-transmitter/</link>
		
		<dc:creator><![CDATA[Mehmet Akın]]></dc:creator>
		<pubDate>Sat, 13 Aug 2022 14:13:01 +0000</pubDate>
				<guid isPermaLink="false">http://fluscon.com/?post_type=product&#038;p=499</guid>

					<description><![CDATA[General Features &#160; Application Areas Liquids , Oils , Air and All of the Gasses Measurement Range 0 &#8230; 100 mbar  / 0 &#8230; 50 bar Temperature 20 &#8230; +125 °C ( Opt.300°C) Connection Measurement 1/2&#8243; Connection Norm G / NPT Cable Union PS520 DIN46350C or M12 PIN PS300 DIN46350A or M12 PIN PS500 DIN46350A or M12 PIN [&#8230;]]]></description>
										<content:encoded><![CDATA[<h3>General Features</h3>
<p>&nbsp;</p>
<table style="height: 714px;" width="717">
<tbody>
<tr>
<td width="260"><strong>Application Areas</strong></td>
<td width="260">Liquids , Oils , Air and All of the Gasses</td>
</tr>
<tr>
<td><strong>Measurement Range</strong></td>
<td>0 &#8230; 100 mbar  / 0 &#8230; 50 bar</td>
</tr>
<tr>
<td><strong>Temperature</strong></td>
<td>20 &#8230; +125 °C ( Opt.300°C)</td>
</tr>
<tr>
<td><strong>Connection Measurement</strong></td>
<td>1/2&#8243;</td>
</tr>
<tr>
<td><strong>Connection Norm</strong></td>
<td>G / NPT</td>
</tr>
<tr>
<td rowspan="5"><strong>Cable Union</strong></td>
<td>PS520 DIN46350C or M12 PIN</td>
</tr>
<tr>
<td>PS300 DIN46350A or M12 PIN</td>
</tr>
<tr>
<td>PS500 DIN46350A or M12 PIN</td>
</tr>
<tr>
<td>PS530 DIN46350A or M12 PIN</td>
</tr>
<tr>
<td>PS560 DIN46350A or M12 PIN</td>
</tr>
<tr>
<td rowspan="2"><strong>Wet Parts</strong></td>
<td>Diaphragm AISI316 L or Ceramic Trunk</td>
</tr>
<tr>
<td> AISI316SS ,AISI304 SS or PVDF</td>
</tr>
<tr>
<td><strong>Connection Parts</strong></td>
<td>AISI304 SS</td>
</tr>
<tr>
<td><strong>Preservation/Housing</strong></td>
<td>Epoxy Coated Aluminum / Plastic</td>
</tr>
<tr>
<td><strong>Analog Output Signal</strong></td>
<td>4&#8230;20 mA / 0&#8230;5 V / 0&#8230;10 V</td>
</tr>
<tr>
<td><strong>Dijital Output Signall</strong></td>
<td>2xPNP ( With AK04  )</td>
</tr>
<tr>
<td><strong>Communication Protocol</strong></td>
<td>Not Included</td>
</tr>
<tr>
<td><strong>Supply Voltage</strong></td>
<td>10 &#8230; 32 VDC</td>
</tr>
<tr>
<td><strong>Protection Class</strong></td>
<td>IP65/IP67 /IP68 With Direct Cable Exit</td>
</tr>
<tr>
<td><strong>Approval</strong></td>
<td>Ex d , Exia</td>
</tr>
<tr>
<td><strong>Precision</strong></td>
<td>% 0,25 Std.</td>
</tr>
<tr>
<td><strong>Repetitivity</strong></td>
<td>% 0,05 FS</td>
</tr>
<tr>
<td><strong>Linearity</strong></td>
<td>% 0,15 FS</td>
</tr>
<tr>
<td><strong>Indicator Options</strong></td>
<td>Compact , Remote ( Seperate )</td>
</tr>
<tr>
<td><strong>Indicator Parameters</strong></td>
<td>Differential Pressure ( All Pressure Units )  , Percentage Value</td>
</tr>
<tr>
<td><strong>Quality Certificates</strong></td>
<td>IS09001 / CE</td>
</tr>
</tbody>